Truong Thanh Aluminium

Product range

Curtain wall, railing & louvre

The sections that make up a building's outer face — mullions and transoms, glass railings, shutters and louvre blades from 0.6 mm.

Alloy & temper
6063 T5, 6063 T6, 6061
Wall thickness
0.6 – 2.0 mm
Standard length
6 m
Finish
Powder, wood grain, electrophoretic, anodised, mill

Three problems, one range

Curtain wall, railing and louvre are grouped because they are all the outside of the building and all fail the same way — through the joint, not through the section. The catalogue reflects that: each system is published as a frame plus the joints, bars and decor boxes that close it.

Façade systems are listed by depth. The deeper the mullion, the greater the span it carries between floors, which is the number that decides the system long before the finish does.

Railing and shutter sections share the GM55 geometry with the architectural range, so a project can run the same bevelled edge from the door frame to the balcony rail without a second die.

Louvre and cladding blades are the thin end of the range — 0.6 to 0.8 mm, in flat, box, slat and reed profiles — where weight per metre matters more than wall thickness.

Systems in this range

Façade depth first, then the railing, shutter and blade systems.

SystemWhat it covers
Façade 52 / 62 / 65Stick curtain-wall mullion and transom sections by system depth, with their matching rails, bases and joints.
Façade 1100The deepest section in the façade range, for the longest unsupported spans.
Railing XingfaGlass railing on the Xingfa geometry: rail bar, box, joint and frame sections, with a 160 insulating-glass door section in the same family.
Railing chamfered edge GM55Chamfered-edge railing sharing the GM55 geometry — main frame, mould and mould base, joint, bar and decor box.
Shutter systemShutter blades, boxes, rails and moulds built on the XF GM55 sections.
Lamri louvre & claddingBlade profiles from 0.6 to 0.8 mm — flat, box, slat and reed — for ceilings, soffits and screening.
Glass leaf & structureThe leaf, bead, base and hanging sections that carry glass into all of the above, published by code in the catalogue.

Where it goes

01

Office & hotel towers

Stick curtain wall, specified by mullion depth against floor-to-floor height.

02

Balustrades

Glass railing to balconies, stairs and walkways, in the same finish as the glazing.

03

Screening & shading

Louvre blades and shutters used to cut solar gain on west-facing elevations.

04

Ceilings & soffits

Lamri cladding blades, where the run is long and the weight per metre is the constraint.

Working to a façade specification?

Send the elevation and the floor-to-floor dimension. We will come back with the system depth that carries it and the sections that go with it.